Monitoring gases is mandatory owing to regulations, and flue gas analysis is utilized for both efficiency and emissions control. Monitoring flue gases has become inexpensive, simpler, and more prevalent as a result of technological advancements.
Image Credit: DyziO/Shutterstock.com
The term "flue" refers to the long pipes that are used to discharge exhaust gases, and are commonly found as chimneys, ducts, or simple pipes. The gases ejected by flues have a wide range of compositions, based on the operations taking place within each facility. Users may conduct a flue gas analysis to detect the concentration of different gases and regulate the burner on a boiler to ensure optimal performance.
Flue gas analysis is essential for evaluating air-to-fuel ratios in combustion for best efficiency. The kind of fuel consumed and the combustion circumstances at each plant define the particular composition of flue gas. For combustion to occur efficiently, whether a facility employs solid, liquid, or gaseous fuels, an appropriate balance of fuel and air must be reached.
It is also crucial to detect contaminants in emissions. Nitrogen dioxide (NO2), sulfur dioxide (SO2), nitric oxide (NO), carbon monoxide (CO), and other pollutants are all measured using a flue gas analyzer. Following detection, equipment can treat flue gas using scrubbers and/or chemical processors for removing contaminants, thus enhancing sustainable development and satisfying EPA and other organizations' regulations.
While working in a fuel-burning environment, it is critical to use the best flue gas analyzers available. The finest portable flue gas analyzers can identify practically any pollutant and make the necessary modifications to obtain the best fuel-to-air ratios in a variety of applications, including boilers, heaters, furnaces, and engine exhaust.
Flue gas analysis is done by inserting a probe into the flue of a boiler, furnace, or other appliance between the last heat exchanger and draft diverter, or indeed any source of make-up air that may enter the flue that did not flow through the combustion process. This is referred to as an "in-situ" examination.
Most probes presently are either electrochemical or infrared, based on the gas being analyzed. Certain values are computed based on gases which are measured and afterward factored based on input fuel qualities. Not all gases are measured directly by all meters; some values are derived based on gasses that are measured and thereafter factored depending on the input fuel characteristics.
In-situ probes are not used by all flue gas analyzers. Some devices deliver flue gases towards the instrument through a tube. This is particularly common with continuous monitoring devices and extremely big systems, where reaching a location in the flue to insert a probe or locate a portable meter is difficult.
To prevent the product being measured from escaping, the tube might have to be heated. To avoid moisture damage to a probe, the flue gases should be cooled and dried in other circumstances. Instrumentation employs a 'Peltier Cooler,' an electrochemical device that creates a cold surface that condenses any moisture in the flue gas before it enters the measurement sensor.
Probes and sensors do not survive indefinitely; certain electrochemical sensors are destructed during the measurement process, while others wear out over time due to exposure to heat and corrosive gases. As a result, infrared sensors are becoming increasingly common for a variety of applications.
However, these are more costly, are not necessarily as precise, and are impacted by dirt, fogged lenses, as well as other application concerns that limit where and how they may be utilized. Most of these problems will be reduced or eliminated if steady progress is made.
After analyzing, transporting, and purifying sample flue gases, moisture is eliminated and the samples are delivered to further processes or a safe vent. If particle matter is present in the flue gas, this adds significant expense to the system as well as additional system maintenance.
Measuring flue gas or burning process parameters (such as CO) is a difficult task for both the measuring device and the user. This is because, in addition to "traditional" responsibilities like commissioning and maintaining all sorts of heating systems, unique projects arise. Not only does this need specialized knowledge, but it also necessitates specialized measurement technology.
A significant flue gas analyzer is a further development of the well-known exhaust gas measurement equipment from Testo, and it offers the same precision and dependability. The most significant distinction is that the newest flue gas analyzer is controlled entirely through an application on a smartphone or tablet.
The application may fully demonstrate the operations of the exhaust gas measuring device as well as the presentation of measurement data. To provide an all-around sealed housing, extra-durable features have been included. The program allows for totally paperless documentation of measurement data, as well as quick e-mail delivery of reports.
Energy Solutions Center. (2020). Flue Gas Analysis. http://cleanboiler.org/flue-gas-analysis
Power. (2010). Flue Gas Analysis as a Furnace Diagnostic Tool. https://www.powermag.com/flue-gas-analysis-as-a-furnace-diagnostic-tool/
Disclaimer: The views expressed here are those of the author expressed in their private capacity and do not necessarily represent the views of AZoM.com Limited T/A AZoNetwork the owner and operator of this website. This disclaimer forms part of the Terms and conditions of use of this website.
Akhlaqul has a passion for engineering, renewable energy, science, and business development.
Please use one of the following formats to cite this article in your essay, paper or report:
Karomah, Akhlaqul. (2022, January 24). An Overview of Flue Gas Analysis. AZoM. Retrieved on May 20, 2022 from https://www.azom.com/article.aspx?ArticleID=21254.
Karomah, Akhlaqul. "An Overview of Flue Gas Analysis". AZoM. 20 May 2022. <https://www.azom.com/article.aspx?ArticleID=21254>.
Karomah, Akhlaqul. "An Overview of Flue Gas Analysis". AZoM. https://www.azom.com/article.aspx?ArticleID=21254. (accessed May 20, 2022).
Karomah, Akhlaqul. 2022. An Overview of Flue Gas Analysis. AZoM, viewed 20 May 2022, https://www.azom.com/article.aspx?ArticleID=21254.
Do you have a review, update or anything you would like to add to this article?
AZoM speaks with Dr. Nicola Ferralis from MIT about his research that has developed a low-cost process of creating carbon fibers from hydrocarbon pitch. This research could lead to the large-scale use of carbon fiber composites in industries that have thus far been limited.
In this interview, AZoM speaks with Marco Enger, Senior Tribologist from GGB, to discuss how nano fillers affect transfer films within tribological systems.
Ahead of their talk on green chemistry and profitability in laboratory research at ChemUK 2022, AZoM spoke with Jacqueline Balian from Gambica and Martyn Fordman from Asynt about encouraging sustainability in the chemical industry.
COXEM's CP-8000+ is a powerful cross section polishing tool that uses an argon ion beam to allow precise, advanced sample preparation. Its state-of-the-art technology means the sample is not deformed and does not suffer any kind of physical damage.
This product profile outlines the background information of ARSST tool that is being used for screening tests and operating in "open cell" mode.
This product profile outlines the Evolution™ Pro UV-Vis Spectrophotometers from Thermo Fisher Scientific.
This article provides an end-of-life assessment of lithium-ion batteries, focusing on the recycling of an ever-growing amount of spent Li-Ion batteries in order to work toward a sustainable and circular approach to battery use and reuse.
Corrosion is the degradation of an alloy caused by its exposure to the environment. Corrosion deterioration of metallic alloys exposed to the atmosphere or other adverse conditions is prevented using a variety of techniques.
Due to the ever-increasing demand for energy, the demand for nuclear fuel has also increased, which has further created a significant increase in the requirement for post-irradiation examination (PIE) techniques.
AZoM.com - An AZoNetwork Site
Owned and operated by AZoNetwork, © 2000-2022